Product Details Portlet

G8HL Automotive Micro ISO relay (Plug-in/PCB)

Low profile relay PCB: Maximum of height is 18.2mm P-in: Maximum of height is 16.7mm

  • The height is approximately half of a typical Micro
    ISO relay.
  • Smaller, less heating and capable to carry high
    current.

Please confirm Omron Safety Precautions for all automotive relays first.
Omron can not guarantee automotive relays before finish making a contract with product specifications.

RoHS適合
本ページは製品カタログからの抜粋した情報を記載しています。その他の製品情報はデータシート他各種データをご覧ください。
ClassificationTerminal formContact structureProtective structureRated coilType
Voltage (V)Resistance (Ω)
Micro ISOFor PCBSPST
(1a)
Simple plastic sealDC12135G8HL-1A4P
For Plug-in ISO150G8HL-1A4T-R
■Ratings
●Operation coil
Rated
voltage(V)
Terminal form(Ω)Rated
current
(mA)
Operating
voltage
(V)
Release
voltage
(V)
Max. of applied voltage
(20A conduct, 100ΩC)
(V)
Service voltage
range
(V)
Rated power
consumption
(mW)

(Surge
suppression)
DC 12135-907.0 or less0.7 or moreDC16, continuousDC10 to 161067
150(1.1k,1/4W)808.0 or less0.7 or more960

●Switching area
ItemPerformance
Contact materialSilver alloy
Rated voltageDC12V
Rated loadResistance load, 20A
Inrush current100A
Continuous carry current*120A*1
Allowable carrying current30A at DC14V (30 min.)*2 (Reference)
Min. Carry / Switching CurrentDC12V 1A

■Performance
ItemStandard value
G8HL-1A4PG8HL-1A4T-R
Voltage drop between terminals200mV or less, 20A
Operating time*310ms or less10ms or less
Release time*310ms or less10ms or less
Insulation
resistance*4
Between coil and terminal10MΩ or more
Between homopolar contacts10MΩ or more
Withstand
voltage*5
Between coil and terminalAC500V for 1min.
Between homopolar contactsAC500V for 1min.
Vibration
tolerance
Durability33Hz 43.1m/s2
Malfunction
(Detecting time:1ms)
20 to 500Hz 43.1m/s2
Shock
resistance
Durability1000m/s2 (Operating time:6ms)
Malfunction
(Detecting time:1ms)
100m/s2 (Operating time:11ms)
Mechanical endurance
(Switching frequency:18,000 times/h)
1,000,000 times
Electrical endurance (Rated load)100,000 times
Ambient temperatur-40 to 100°C
Ambient humidity35 to 85%RH
Weight13g14g
Note: All values above are measured in early time under an ambient temperature of +20°C and humidity of 65% unless stated.
*1. The value stated is at maximum temperature in a guaranteed ambient temperature.
*2. This is an acceptable current-carrying value in abnormal, and this is not a value which guarantee a repeat current-carrying.
Please check under actual use condition before use.
*3. It changes depend on how the rated voltage is operated, but bounce-time is not included.
*4. Measured at DC500V.
*5. Measured under 1mA of leak current, 50/60Hz for 1minute.
G8HL-P Relay with PCB Terminals
G8HL:Dimensions1

G8HL-T Relay with Plug-in Terminals
G8HL:Dimensions1