Product Details Portlet

G3VM-81G1 MOS FET Relays

Analog-switching MOS FET Relays in 80-V Load Voltage Series, SOP Package.

  • Continuous load current of 350 mA.
RoHS適合
本ページは製品カタログからの抜粋した情報を記載しています。その他の製品情報はデータシート他各種データをご覧ください。
Package type Contact form Terminals Load voltage (peak value)* Model Minimum package quantity
Number per tube Number per tape and reel
SOP4 1a
(SPST-NO)
Surface-mounting terminals 80 V G3VM-81G1 100  
G3VM-81G1(TR) --- 2,500
* The AC peak and DC value are given for the load voltage.
Absolute Maximum Ratings (Ta = 25ºC)
Item Symbol Rating Unit Measurement Conditions
Input LED forward current IF 50 mA  
LED forward current reduction rate △IF/℃ -0.5 mA/ºC Ta ≥ 25ºC
LED reverse voltage VR 5 V  
Connection temperature TJ 125 ºC  
Output Load voltage (AC peak/DC) VOFF 80 V  
Continuous load current (AC peak/DC) IO 350 mA  
ON current reduction rate △IO/℃ -3.5 mA/ºC Ta ≥ 25ºC
Connection temperature TJ 125 ºC  
Dielectric strength between I/O (See note 1.) VI-O 1,500 Vrms AC for 1 min
Ambient operating temperature Ta -20 to + 85 ºC With no icing or condensation
Ambient storage temperature Tstg -40 to + 125 ºC With no icing or condensation
Soldering temperature (10 s) 260 ºC 10 s
Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side.

Electrical Characteristics (Ta = 25ºC)
Item Symbol Minimum Typical Maximum Unit Measurement Conditions
Input LED forward voltage VF 1.0 1.15 1.3 V IF=10 mA
Reverse current IR --- --- 10 µA VR= 5V
Capacitance between terminals CT --- 15 --- pF V=0,
f=1MHz
Trigger LED forward current IFT --- 1.0 4.0 mA IO=350mA
Output Maximum resistance with output ON RON --- 1.0 1.2 Ω IF = 5mA
IO=350mA
Current leakage when the relay is open ILEAK --- 0.2 1.0 nA VOFF=30V,
Ta= 50ºC
Capacitance between terminals COFF --- 30 40 pF V = 0, f = 100 MHz
Capacitance between I/O terminals CI-O --- 0.8 --- pF f=1 MHz,
Vs = 0V
Insulation resistance between I/O terminals RI-O 1,000 108 --- VI-O=500 VDC,
RoH ≤ 60%
Turn-ON time tON --- 0.3 0.5 ms IF=5 mA,
RL=200Ω
VDD=20V(See note 2.)
Turn-OFF time tOFF --- 0.3 0.5 ms
Note: 2.Turn-ON and Turn-OFF Times

Surface-mounting Terminals
Weight: 0.1 g
G3VM-81G1:Dimensions1
Note: The actual product is marked differently from the image shown here.

Actual Mounting Pad Dimensions
(Recommended Value, Top View)
G3VM-81G1:Dimensions2

Terminal Arrangement / Internal Connections
(TOP VIEW)
G3VM-81G1:Dimensions3

Note: The actual product is marked differently from the image shown here.
* The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold.