Product Details Portlet

G3VM-61H1 MOS FET Relays

MOS FET Relays Designed for Switching Minute Signals and Analog Signals.

  • Continuous load current of 400 mA.
RoHS適合
本ページは製品カタログからの抜粋した情報を記載しています。その他の製品情報はデータシート他各種データをご覧ください。
Package type Contact form Terminals Load voltage (peak value)* Model Minimum package quantity
Number per tube Number per tape and reel
SOP6 1a
(SPST-NO)
Surface-mounting terminals 60 V G3VM-61H1 75 ---
G3VM-61H1(TR) --- 2,500
* The AC peak and DC value are given for the load voltage.
Absolute Maximum Ratings (Ta = 25ºC)
Item Symbol Rating Unit Measurement Conditions
Input LED forward current IF 50 mA
LED forward current reduction rate △IF/℃ -0.5 mA/ºC Ta ≥ 25ºC
LED reverse voltage VR 5 V
Connection temperature TJ 125 ºC
Output Load voltage (AC peak/DC) VOFF 60 V
Continuous load current Connection A IO 400 mA Connection A: AC peak/DC
Connection B and C: DC
Connection B 400
Connection C 800
ON current reduction rate Connection A △IO/℃ -4.0 mA/ºC Ta ≥ 25ºC
Connection B -4.0
Connection C -8.0
Connection temperature TJ 125 ºC
Dielectric strength between I/O (See note 1.) VI-O 1,500 Vrms AC for 1 min
Ambient operating temperature Ta -40 to + 85 ºC With no icing or condensation
Ambient storage temperature Tstg -55 to + 125 ºC With no icing or condensation
Soldering temperature (10 s) 260 ºC 10 s
Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side.
G3VM_61H1:Ratings/Characteristics1

Electrical Characteristics (Ta = 25ºC)
Item Symbol Minimum Typical Maximum Unit Measurement Conditions
Input LED forward voltage VF 1.0 1.15 1.3 V IF=10 mA
Reverse current IR --- --- 10 µA VR= 5V
Capacitance between terminals CT --- 30 --- pF V=0,
f=1MHz
Trigger LED forward current IFT --- 1.6 3 mA IO=400mA
Output Maximum resistance with output ON Connection A RON --- 1 2 Ω IF = 5mA
IO=400mA
Connection B --- 0.5 1 Ω IF = 5mA
IO=400mA
Connection C --- 0.25 --- Ω IF = 5mA
IO=800mA
Current leakage when the relay is open ILEAK --- --- 1.0 µA VOFF=60V
Capacitance between terminals COFF --- 130 --- pF V = 0, f = 1 MHz
Capacitance between I/O terminals CI-O --- 0.8 --- pF f=1 MHz,
Vs = 0V
Insulation resistance between I/O terminals RI-O 1,000 108 --- VI-O=500VDC,
RoH ≤ 60%
Turn-ON time tON --- 0.8 2.0 ms IF=5 mA,
RL=200Ω
VDD=20V
(See note 2.)
Turn-OFF time tOFF --- 0.1 0.5 ms
Note: 2. Turn-ON and Turn-OFF Times
G3VM_61H1:Ratings/Characteristics2

Surface-mounting Terminals
Weight: 0.13 g
G3VM-61H1:Dimensions1
Note: The actual product is marked differently from the image shown here.

Actual Mounting Pad Dimensions
(Recommended Value, Top View)
G3VM-61H1:Dimensions2

Terminal Arrangement/Internal Connections
G3VM-61H1:Dimensions3
Note: The actual product is marked differently from the image shown here.