Product Details Portlet

G3VM-61G2 MOS FET Relays

Ultrasensitive MOS FET Relays in 60 V Load series for electric power saving.

  • Trigger LED forward current of 1 mA (maximum)
    facilitates power saving designs and prolonged battery life.
  • Continuous load current of 400 mA.
RoHS適合
本ページは製品カタログからの抜粋した情報を記載しています。その他の製品情報はデータシート他各種データをご覧ください。
Package typeContact formTerminalsLoad voltage (peak value)*Continuous load current (peak value) *ModelMinimum package quantity
Number per tubeNumber per tape and reel
SOP41a
(SPST-NO)
Surface-mounting
terminals
60 V400 mAG3VM-61G2100 pcs.---
G3VM-61G2(TR)---2500 pcs.
*The AC peak and DC value are given for the load voltage and continuous load current.
Note:To order tape packaging for Relays with surface-mounting terminals, add "(TR)" or "(TR05)" to the end of the model number.
Absolute Maximum Ratings (Ta = 25ºC)
ItemSymbolRatingUnitMeasurement Conditions
InputLED forward currentIF50mA
LED forward current reduction rateΔ IF/ºC-0.5mA/ºCTa ≥ 25ºC
LED reverse voltageVR5V
Connection temperatureTJ125ºC
OutputLoad voltage (AC peak/DC)VOFF60V
Continuous load current (AC peak/DC)IO400mA
ON current reduction rateΔ IO/ºC-4.0mA/ºCTa ≥ 25ºC
Pulse ON currentlop1200mAt=100 ms,
Duty=1/10
Connection temperatureTJ125ºC
Dielectric strength between I/O *VI-O1,500VrmsAC for 1 min
Ambient operating temperatureTa-40 to + 85ºCWith no icing or condensation
Ambient storage temperatureTstg-55 to + 125ºCWith no icing or condensation
Soldering temperature---260ºC10 s
* The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side.

Electrical Characteristics (Ta = 25ºC)
ItemSymbolMinimumTypicalMaximumUnitMeasurement Conditions
InputLED forward voltageVF1.01.151.3VIF=10 mA
Reverse currentIR------10µAVR= 5V
Capacitance between terminalsCT---30---pFV=0,
f=1MHz
Trigger LED forward currentIFT (IFC) *2---0.41mAIO=400mA
Release LED forward currentIFC (IFT) *20.1------mAIOFF=100µA
OutputMaximum resistance with output ONRON---12ΩIF = 2mA
IO=400mA
Current leakage when the relay is openILEAK---11000nAVOFF=60V
Capacitance between terminalsCoff---130---pFV = 0, f = 1 MHz
Capacitance between I/O terminalsCI-O---0.8---pFf=1 MHz,
Vs = 0V
Insulation resistance between I/O terminalsRI-O1,000108---VI-O=500VDC,
RoH ≤ 60%
Turn-ON timetON---38msIF=2 mA,
RL=200Ω
VDD=20V *1
Turn-OFF timetOFF---13
*1. Turn-ON and Turn-OFF Times


*2. These values are for Relays with NC contacts
Surface-mounting Terminals
Weight: 0.1 g
G3VM-61G2/D1:Dimensions1
Note:The actual product is marked differently from the image shown here.
Actual Mounting Pad Dimensions (Recommended Value, Top View)
G3VM-61G2/D1:Dimensions2


Terminal Arrangement/Internal Connections
(Top View)

SOP (Small Outline Package)
SOP 4-pin

Note: 1. The actual product is marked differently from the image shown here.
Note: 2. "G3VM" does not appear in the model number on the Relay.
Note: 3. The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold.