Product Details Portlet

D2MV Miniature Basic Switch

Highly reliable Miniature Basic Switch in spite of its Ultra-low Load action

  • Twin crossbar contact employed for exceptionally high contact reliability.
  • Unique internal mechanism that ensures high contact reliability even in micro load operations. Applicable for detection of light objects.
RoHS適合
Model 2D/3D CAD
D2MV-01-1C1 Download
D2MV-01-1C2 Download
D2MV-01-1C3 Download
D2MV-01L-1C3 Download
D2MV-01L11-1C3 Download
D2MV-01L111-1C3 Download
D2MV-01L13-1C3 Download
D2MV-01L2-1C3 Download
D2MV-01L22-1C3 Download
本ページは製品カタログからの抜粋した情報を記載しています。その他の製品情報はデータシート他各種データをご覧ください。
Actuator Max. Operating Force (OF) 1 A 0.1 A
Pin plunger

img

0.10 N {10 gf}
D2MV-1-1C1 D2MV-01-1C1
0.25 N {25 gf}
D2MV-1-1C2 D2MV-01-1C2
0.49 N {50 gf}
D2MV-1-1C3 D2MV-01-1C3
Short hinge lever

img

0.49 N {50 gf}
D2MV-1L11-1C3 D2MV-01L11-1C3
Hinge lever

img

0.29 N {30 gf}
D2MV-1L-1C3 D2MV-01L-1C3
Long hinge lever

img

0.15 N {15 gf}
D2MV-1L111-1C3 D2MV-01L111-1C3
Simulated roller lever

img

0.29 N {30 gf}
D2MV-1L13-1C3 D2MV-01L13-1C3
Short hinge roller lever

img

0.49 N {50 gf}
D2MV-1L22-1C3 D2MV-01L22-1C3
Hinge roller lever

img

0.29 N {30 gf}
D2MV-1L2-1C3 D2MV-01L2-1C3
Note: Consult your OMRON representative for details on SPST-NO and SPST-NC models.
Contact Form
SPDT
Separator (Sold Separately), Actuator (Sold Separately), Terminal Connector (Sold Separately)
→Refer to "Basic Switch Common Accessories"
Model

Rated voltage
Item
D2MV-1
D2MV-01
Resisteve load
125VAC

1A

0.1A
30VDC 1A 0.1A
Note: The ratings values apply under the following test conditions:
Ambient temperature: 20±2ºC
Ambient humidity: 65±5%
Operating frequency: 30 operations/min

Characteristics
Permissible operating speed
1 mm to 1 m/s (pin plunger models)
Permissible operating frequency
Mechanical: 300 operations/min max. (pin plunger models)
Electrical: 60 operations/min max.
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance (initial value)
D2MV-01 models: 50 mΩ max.
D2MV-1 models: 30 mΩ max.
Dielectric strength * 1
1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and the ground
1,500 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal parts
Vibration resistance * 2
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Destruction: Models with OF of 0.10 N: 150 m/s2 {approx. 15G} max.
Models with OF between 0.25 and 0.49 N: 400 m/s2 {approx. 40G} max.
Malfunction*1: 100 m/s2 {approx. 10G} max.
Durability * 3
Mechanical: 10,000,000 operations min.(60 operations/min)
Electrical: D2MV-1 models:500,000 operations min.(30 operations/min)
D2MV-01 models:1,000,000 operations min.
(30 operations/min)
Degree of protection
IEC IP40
Degree of protection against electric shock
Class I
Proof tracking index (PTI)
175
Ambient operating temperature
-25ºC to +80ºC (at ambient humidity of 60% max.)
(with no icing or condensation)
Ambient operating humidity
85% max. (for 5ºC to 35ºC)
Weight
Approx. 6 g (pin plunger models)
Note: The data given above are initial values.
  * 1 The values for dielectric strength shown are for models with a Separator (refer to "Micro Switch Common Accessories").
  * 2 The values are at Free Position and Total Travel Position values for pin plunger, and Total Travel Position value for lever. Close or open circuit of the contact is 1ms max.
Note: 1. All units are in millimeters unless otherwise indicated.
  2. The RF values indicated in parentheses are for cases where the lever weight is not applied to the plunger.
  3. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
  4. The operating characteristics are for operation in the A direction ().

Pin Plunger Models img
D2MV-1-1C
D2MV-01-1C
Note: The in the model number
is for the OF code.
D2MV:Dimensions1
Model
D2MV-1-1C1
D2MV-01-1C1
D2MV-1-1C2
D2MV-01-1C2
D2MV-1-1C3
D2MV-01-1C3
OF max.
RF min.
0.10 N {10 gf}
0.005 N {0.5 gf}
(reference value)
0.25 N {25 gf}
0.01 N {1 gf}
(reference value)
0.49 N {50 gf}
0.02 N {2 gf}
(reference value)
PT max.
OT min.
MD max.
1.2 mm
1.3 mm
0.25 mm
OP
14.7±0.4 mm

Short Hinge Lever Models img
D2MV-1L11-1C3
D2MV-01L11-1C3
D2MV:Dimensions2
Model
D2MV-1L11-1C3
D2MV-01L11-1C3
OF max.
RF min.
0.49 N {50 gf}
0.04 N {4 gf}(referenve value)
PT max.
OT min.
MD max.
1.7 mm
1.0 mm
0.4 mm
OP
15.2±0.5 mm
Note: The indicated reference values of RF are for cases where the lever weight is not applied to the plunger.
Hinge Lever Models img
D2MV-1L-1C3
D2MV-01L-1C3
D2MVDimensions3
Model
D2MV-1L-1C3
D2MV-01L-1C3
OF max.
RF min.
0.29 N {30 gf}
0.02 N {2 gf}(referenve value)
PT max.
OT min.
MD max.
3.3 mm
2.1 mm
0.7 mm
OP
15.2±1.2 mm
Note: The indicated reference values of RF are for cases where the lever weight is not applied to the plunger.
Long Hinge Lever Models img
D2MV-1L111-1C3
D2MV-01L111-1C3
D2MV:Dimensions4
Model
D2MV-1L111-1C3
D2MV-01L111-1C3
OF max.
RF min.
0.15 N {15 gf}
0.01 N {1 gf}(reference value)
PT max.
OT min.
MD max.
6.0 mm
4.0 mm
1.4 mm
OP
15.2±2.6 mm
Note: The indicated reference values of RF are for cases where the lever weight is not applied to the plunger.
Simulated Roller Lever Models img
D2MV-1L13-1C3
D2MV-01L13-1C3
D2MV:Dimensions5
Model
D2MV-1L13-1C3
D2MV-01L13-1C3
OF max.
RF min.
0.29 N {30 gf}
0.02 N {2 gf}(reference value)
PT max.
OT min.
MD max.
3.3 mm
1.9 mm
0.7 mm
OP
18.7±1.2 mm
Note: The indicated reference values of RF are for cases where the lever weight is not applied to the plunger.

Short Hinge Roller Lever Models img
D2MV-1L22-1C3
D2MV-01L22-1C3
D2MV:Dimensions6
Model
D2MV-1L22-1C3
D2MV-01L22-1C3
OF max.
RF min.
0.49 N {50 gf}
0.04 N {4 gf}(reference value)
PT max.
OT min.
MD max.
1.7 mm
1.0 mm
0.4 mm
OP
20.7±0.6 mm
Note: The indicated reference values of RF are for cases where the lever weight is not applied to the plunger.
Hinge Roller Lever Models
D2MV-1L2-1C3
D2MV-01L2-1C3
D2MVDimensions7
Model
D2MV-1L2-1C3
D2MV-01L2-1C3
OF max.
RF min.
0.29 N {30 gf}
0.02 N {2 gf}(reference value)
PT max.
OT min.
MD max.
3.3 mm
2.1 mm
0.7 mm
OP
20.7±1.2 mm
Note: The indicated reference values of RF are for cases where the lever weight is not applied to the plunger.

Cautions

●Handling

Do not apply excessive shock. Doing so may cause damage to the Switch's internal components because they designed for a small load.

●Soldering

•Terminal connections Complete the soldering at the iron tip temperature between 250 to 350°C (60W) within 5 seconds, and do not apply any external force for 1 minute after soldering.
Apply minimum amount of flux required. It may result in contact failure once the flux penetrates into the internal part of the Switch.

Correct Use

●Mounting

•Use M3 mounting screw with plane washers or spring washers to securely mount the Switch. Tighten the screws to a torque of 0.39 to 0.59 Nm {4 to 6 kgfcm}.

●Mounting Direction

•For a Switch with an actuator, mount the Switch in a direction where the actuator weight will not be applied to the Switch.
Since the Switch is designed for a small load, its resetting force is small. Therefore, resetting failure may occur if unnecessary load is applied to the Switch.

●Using Micro Loads

•Using a model for ordinary loads to open or close the contact of a micro load circuit may result in faulty contact. Use models that operate in the following range. However, even when using micro load models within the following operating range, if inrush current occurs when the contact is opened or closed, it may increase the contact wear and so decrease durability. Therefore, insert a contact protection circuit where necessary. The minimum applicable load is the N-level reference value. This value indicates the malfunction reference level for the reliability level of 60% (λ60).
(JIS C5003)
The equation, λ60=0.5×10-6/ operations indicates that the estimated malfunction rate is less than 1/ 2,000,000 operations with a reliability level of 60%.