Product Details Portlet

D2MC Low-torque Basic Switch

Highly Reliable Rotary-action Switch for Low Torque Operation (0.5 mN·m )

  • 0.5-A rated model employs crossbar gold-alloy contacts for excellent contact reliability in the micro load range.
  • Long durability (10,000,000 mechanical operations min.) through use of a movable coil spring.
RoHS適合
本ページは製品カタログからの抜粋した情報を記載しています。その他の製品情報はデータシート他各種データをご覧ください。
Direction of actuation Operating Torque (OTq) 5A 0.5A
Clockwise
0.5mN·m{5.1 gf·cm}
D2MC-5E D2MC-01E
0.75mN·m {7.6 gf·cm}
D2MC-5F D2MC-01F
1.00mN·m {10.2 gf·cm}
D2MC-5H D2MC-01H
Counterclockwise
0.5mN·m {5.1 gf·cm}
D2MC-5EL D2MC-01EL
0.75mN·m {7.6 gf·cm}
D2MC-5FL D2MC-01FL
1.00mN·m {10.2 gf·cm}
D2MC-5HL D2MC-01HL
Note: All the models listed here are supplied without actuator lever. If an actuator lever is required, please order separately by indicating the model number of the actuator lever (CAA1M).
Contact Form (SPDT)
Ratings
 
Item
Model
Rated voltage
Resistive load
D2MC-5 125VAC
250VAC
5A
5A
D2MC-01 125VAC 0.5A
30VDC 0.5A
Note: The ratings values apply under the following test conditions:
Ambient temperature: 20±2ºC
Ambient humidity: 65±5%
Operating frequency: 30 operations/min.

Characteristics
Item
D2MC-5
D2MC-01
Permissible operating speed
1ºC to 360ºC/sec
Permissible operating frequency
Mechanical: 240 operations/min max.
Electrical: 30 operations/min max.
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
(initial value)
20 mΩ max. 100 mΩ max.
Dielectric strength
600 VAC, 50/60 Hz for 1 min between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal part
Vibration
resistance * 1
Malfunction:10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Durability: 1,000 m/s2 {approx. 100G} max.
Malfunction * 1: Models with OTq of 0.5 mN · m: 100 m/s2 {10 G} max.
Models with OTq of 0.75 mN · m: 100 m/s2 {10 G} max.
Models with OTq of 1.00 mN · m: 200 m/s2 {20 G} max.
Durability * 2
Mechanical: 10,000,000 operations min.
(60 operations/min)
Electrical: 100,000 operations min.
(30 operations/min)
Mechanical: 10,000,000 operations min.(60 operations/min)
Electrical: 100,000 operations min.(30 operations/min)
Degree of protection
IEC IP40
Degree of protection against electric shock
Class I
Proof tracking index (PTI)
175
Ambient operating temperature
-25ºC to +80ºC (at ambient humidity of 60% max.)
(with no icing or condensation)
Ambient operating humidity
35% to 85% max. (for +5 ºC to +35ºC)
Weight
Approx. 10 g
Note: The data given above are initial values.
  *1 Close or open circuit of the contact is 1ms max.
  *2 For testing conditions, consult your OMRON sales representative.
Ratings
 
Item
Model
Rated voltage
Resistive load
D2MC-5 125VAC
250VAC
5A
5A
D2MC-01 125VAC 0.5A
30VDC 0.5A
Note: The above rating values apply under the following test conditions.
(1) Ambient temperature: 20±2ºC
(2) Ambient humidity: 65±5%
(3) Operating frequency: 30 operations/min

Characteristics
Item
D2MC-5
D2MC-01
Permissible operating speed
1ºC to 360ºC/sec
Permissible operating frequency
Mechanical: 240 operations/min max.
Electrical: 30 operations/min max.
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
(initial value)
20 mΩ max. 100 mΩ max.
Dielectric strength
600 VAC, 50/60 Hz for 1 min between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal part
Vibration resistance
(see note 2)
Malfunction:10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
(see note 2)
Destruction: 1,000 m/s2 {100 G} max.
Malfunction: Models with OTq of 0.5 mN · m: 100 m/s2 {10 G} max.
Models with OTq of 0.75 mN · m: 100 m/s2 {10 G} max.
Models with OTq of 1.00 mN · m: 200 m/s2 {20 G} max.
Durability
(see note 3)
Mechanical: 10,000,000 operations min.
(60 operations/min)
Electrical: 100,000 operations min.
(30 operations/min)
Mechanical: 10,000,000 operations min.
(60 operations/min)
Electrical: 100,000 operations min. (30 operations/min,
125 VAC,30 VDC0.1A)
Degree of protection
IEC IP40
Degree of protection against electric shock
Class I
Proof tracking index (PTI)
175
Ambient operating temperature
-25ºC to 80ºC (at ambient humidity of 60% max.)
(with no icing or condensation)
Ambient operating humidity
35% to 85% max. (for 5 ºC to 35ºC)
Weight
Approx. 10 g
Note: 1. The data given above are initial values.
  2. Malfunction:1ms max.
  3. For testing conditions,contact your OMRON sales representative.
Note:  1. The in the model number are for the Ratings and OTq code. See the "List of Models" for available combinations of models.
  2. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
  3. The operating characteristics are for operation in the A direction ().
Clockwise (CW)
D2MC-
D2MC:dimensions2
D2MC:dimensions2
 


Model
D2MC-5E
D2MC-01E
D2MC-5F
D2MC-01F
D2MC-5H
D2MC-01H
OTq
max.
RTq min.
0.5 mN·m
{5.1gf·cm}
0.06mN·m
{0.6gf·cm}
0.75 mN·m
{7.6gf·cm}
0.09mN·m
{0.9gf·cm}
1.0mN·m
{10.2gf·cm}
0.13mN·m
{1.3gf·cm}
PT max.
OT min.
MD min.
RT min.
21º
17º

21º
17º

21º
17º

TT min.
FP
38º
15±3º (See note 3)

Counterclockwise (CCW)
D2MC-L
D2MC:dimensions2D2MC:dimensions2
 
 

Model
D2MC-5EL
D2MC-01EL
D2MC-5FL
D2MC-01FL
D2MC-5HL
D2MC-01HL
OTq
max.
RTq min.
0.5 mN·m
{5.1gf·cm}
0.06mN·m
{0.6gf·cm}
0.75 mN·m
{7.6gf·cm}
0.09mN·m
{0.9gf·cm}
1.0mN·m
{10.2gf·cm}
0.13mN·m
{1.3gf·cm}
PT max.
OT min.
MD min.
RT min.
21º
17º

21º
17º

21º
17º

TT min.
FP
38º
15±3º (See note 3)

Cautions

Connecting to the tab terminal #205 Insert the receptacle for #205 straight toward the terminal. Applying excessive external force horizontally or vertically may cause deformation of terminals and may damage the housings.

Correct Use

●Mounting/Soldering

•Use M3 mounting screw with plane washers or spring washers to securely mount the Switch. Tighten the screws to a torque of 0.2 to 0.29 Nm {2 to 3 kgfcm}.