Product Details Portlet

XG4A MIL Plugs with Long Locks (MIL Standards)

The Mainstream of Circuit Board Connectors conforming MIL Standards with Improved Design.

  • Our new production system improves reliability.
  • Space-saving Box-type Plugs (XG4C) available.
  • IDC Plugs (XG4E) can be used for relaying.
  • An endless number of combinations can be made using the XG-5 IDC Connectors for discrete wires, XG8 Original Plugs, and the XG2 IDC Connectors for PCBs.
  • The Original Plugs (XG8) and the Box-type Plugs (XG4C) can be locked using Lock Levers.
  • Conform to MIL standards (MIL-C-83503).
  • UL standards (file No. E103202) (All XG4 models except those with XG4U)
RoHS適合
Model 2D/3D CAD
XG4A-1031 Download
XG4A-1034 Download
XG4A-1071 Download
XG4A-1074 Download
XG4A-1431 Download
XG4A-1434 Download
XG4A-1631 Download
XG4A-1634 Download
XG4A-2031 Download
XG4A-2034 Download
XG4A-2631 Download
XG4A-2634 Download
XG4A-3031 Download
XG4A-3034 Download
XG4A-3431 Download
XG4A-3434 Download
XG4A-4031 Download
XG4A-4034 Download
XG4A-5031 Download
XG4A-5034 Download
XG4A-5071 Download
XG4A-5074 Download
XG4A-6031 Download
XG4A-6034 Download
XG4A-6071 Download
XG4A-6074 Download
XG4A-6431 Download
XG4A-6434 Download
XG4A-6471 Download
XG4A-6474 Download
本ページは製品カタログからの抜粋した情報を記載しています。その他の製品情報はデータシート他各種データをご覧ください。
Use in Combination with Strain-relief Sockets.


No. of contacts
No. of polarizing slots
Plugs with straight DIP terminals
Plugs with right-angle DIP terminals

10 0 XG4A-1071 XG4A-1074
1 XG4A-1031 XG4A-1034
14 1 XG4A-1431 XG4A-1434
16 1 XG4A-1631 XG4A-1634
20 1 XG4A-2031 XG4A-2034
26 1 XG4A-2631 XG4A-2634
30 1 XG4A-3031 XG4A-3034
34 1 XG4A-3431 XG4A-3434
40 1 XG4A-4031 XG4A-4034
50 1 XG4A-5031 XG4A-5034
2 * XG4A-5071 XG4A-5074
60 1 XG4A-6031 XG4A-6034
2 * XG4A-6071 XG4A-6074
64 1 XG4A-6431 XG4A-6434
2 * XG4A-6471 XG4A-6474
Note: Polarizing slot pitch is 22.86 mm.

Item

MIL Sockets: XG4M
Relay Plug: XG4E

MIL Plugs: XG4A
Box-type Plugs: XG4C
Board-to-board Sockets: XG4H

Rated current
1A 3A *
Rated voltage
AC250V AC300V
Contact resistance
20 mΩ max. (at 20 mV, 100 mA max.)
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Dielectric strength
500 VAC for 1 min (leakage current: 1 mA max.)
Total insertion force
1.96 N max. per contact
Removal force
0.39 N min. (with test gauge, t= 0.64 mm)
Insertion durability
50 times

Ambient operating temperature

Operating: -55 to 105℃ (with no icing at low temperature)
*The rated current will depend on the Socket you are using. It is 1 A using the XG4M for example.
(Unit: mm)
XG4A-□□31/-□□71(With straight DIP terminals)
XG4A-□□34/-□□74 (With right-angle DIP terminals)


形XG4A:外形1

Mounting view (BOTTOM VIEW)
形XG4A:外形1

Table of Dimensions
Dimensions (mm)

No. of contacts

A B C D E F
10 32.0 17.5 10.16 21.8 27.9 46.4
14 37.1 22.6 15.24 26.9 33.0 51.5
16 39.6 25.2 17.78 29.5 35.6 54.1
20 44.7 30.2 22.86 34.5 40.6 59.1
26 52.3 37.9 30.48 42.2 48.3 66.8
30 57.4 42.9 35.56 47.2 53.3 71.8
34 62.5 48.0 40.64 52.3 58.4 76.9
40 70.1 55.6 48.26 59.9 66.0 84.5
50 82.8 68.3 60.96 72.6 78.7 97.2
60 95.5 81.0 73.66 85.3 91.4 109.9
64 100.6 86.1 78.74 90.4 96.5 115.0
Note: See page 16 for details on the availability (10-contact Connectors) and pitch (with 50, 60, or 64-contact Connectors) of polarity slots.